• 查询稿件
  • 获取最新论文
  • 知晓行业信息

基于单相冷板式液冷技术的铁路数据中心液冷系统微模块方案设计

Micro module of railway data center liquid cooling system based on single-phase cold plate liquid cooling technology

  • 摘要: 针对铁路数字化转型加速所导致的铁路数据中心机房能耗激增、制冷成本大幅增加等问题,提出一种基于单相冷板式液冷技术的铁路数据中心液冷系统微模块设计方案。文章从配套设施、实施策略等多个角度,研究液冷技术在减少机房能源消耗、降低数据中心电源使用效率(PUE,Power Usage Effectiveness)值及提高空间利率等方面的价值,并根据预期效果,对采用该方案后数据中心的能耗及PUE值等进行了分析。在某数据中心机房的实验结果表明,该方案预期PUE值能够满足国家相关政策要求,具备在铁路数据中心应用的优势。

     

    Abstract: In order to solve the problems of energy consumption surge and cooling cost increase in railway data center rooms caused by the acceleration of railway digital transformation, this paper proposed a micro module design scheme for railway data center liquid cooling system based on single-phase cold plate liquid cooling technology, studied the value of liquid cooling technology in reducing energy consumption in data centers, lowering Power Usage Effectiveness (PUE) values, and improving spatial efficiency from multiple perspectives such as supporting facilities and implementation strategies. Based on the expected results, the paper analyzed the energy consumption and PUE values of data centers after adopting this scheme, and conducted an experiment. The experimental results in a data center computer room indicate that the expected PUE value of this scheme can meet the requirements of relevant national policies and has the advantage of being applied in railway data centers.

     

/

返回文章
返回